Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Arch. cardiol. Méx ; 75(2): 141-147, abr.-jun. 2005. ilus, tab
Article in Spanish | LILACS | ID: lil-631884

ABSTRACT

Se describen los hallazgos Ecocardiográficos en seis pacientes con disfunción por obstrucción intermitente de prótesis (DOIP) mecánica de disco en posición mitral. Todos con cuadro clínico de instalación gradual, con disnea progresiva de varias semanas de evolución. Se les practicó ETT con registros Bd y de modo M "orientado" desde apical 4/C y se compararon los hallazgos con un grupo control de 14 pts con prótesis normo-funcionante. En el grupo de DOIP, todos presentaban un retardo variable en la apertura de la prótesis, registrada como un "escalón" protodiastólico en el modo M. En la mitad la disfunción fue por trombos. En dos porpannus. Tres se operaron. Uno se trombolizó. En dos se incrementó el tratamiento con heparina IV y con anticoagulante oral. Ninguno falleció durante el manejo agudo de la disfunción intermitente. Dos fallecieron: uno siete meses después en insuficiencia cardíaca y otro, un año después por retrombosis protésica. En pacientes con prótesis mecánica en posición mitral y disnea progresiva, la presencia de un retardo variable en la apertura de la prótesis, es diagnóstica de DOIP y requiere manejo urgente con trombólisis o cirugía.


Echocardiographic findings in six patients with obstructive intermittent dysfunction of mechanical disc prosthetic mitral valve (OIPD) are described. All with a clinical picture of gradual installation and progressive dyspnea of several weeks of evolution. TTE with Bd recordings were performed in all of them with "oriented" M mode from apical 4/C view. The findings were compared with a control group of 14 patients with normal prosthetic valves. In the group of OIDP, all patients displayed a variable delay in the opening of the prosthetic disc, registered as a "protodiastolic step" in M mode. In three patients, the dysfunction was due to a thrombus. In two, due to pannus. Three were operated. One with thrombolysis. In two, the treatment consisted of heparin and increased oral anticoagulation. None die during the acute handling of the intermittent dysfunction. Two patients died: one seven months later due to cardiac failure and the other a year later due to prosthetic rethrombosis. In patients with mechanical prosthetic valve in mitral valve position and progressive dyspnea, the presence of a variable delay in the opening of the prosthesis is diagnostic of OIDP and requires urgent handling with thrombolysis or surgery. (Arch Cardiol Mex 2005; 75: 141-147).


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Echocardiography, Doppler, Color , Heart Valve Prosthesis/adverse effects , Mitral Valve , Prosthesis Failure , Case-Control Studies , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation , Mitral Valve/pathology , Mitral Valve/surgery , Postoperative Complications
SELECTION OF CITATIONS
SEARCH DETAIL